How much will you save with a wall-mounted heat pump?
Describe your home, then choose one of the 40 wall-mounted heat pumps we install. The calculation replays ten real winters, hour by hour, with each unit’s certified ratings and Hydro-Québec’s 2026 rate. Everything is detailed, and everything can be changed.
- 40 certified models
- 175,124 hours of real weather
- 12 months in detail
- 2026 Hydro-Québec rate
- 40 models
- 10 real winters
- 2026 rate
Tell us about your home
Calculated for the Laval area: the average of ten real winters (2016 to 2025) at the Trudeau and Mirabel airports.
Choose your heat pump
Brand
Series from entry level to top performer
Capacity
Today, you heat with…
- over years
- off your heating bill
- LogisVert subsidy:
- Heating today
- Heating with the heat pump
- Savings on heating
- Cooling today
- Cooling with the heat pump
- Difference on cooling
Month by month
What heating and cooling the room costs each month, averaged over the 2016 to 2025 winters. Tap a column to read its figures.
See the month-by-month table
| Month | Average temperature | Heat required (kWh) | Supplied by the heat pump | Today | With the heat pump | Savings |
|---|
Degree by degree: what heats, and when?
The colder it gets, the more heat the room needs, and the less a heat pump can supply. Where the two curves cross, backup heat takes over.
The year’s heat, degree by degree Each column: all the heat of a year at that temperature.
See the degree-by-degree table
| Outdoors | Hours per year | Room need (BTU/h) | Heat pump max. heat (BTU/h) | Heat for the year (kWh) | By the heat pump | By backup heat | Heat pump electricity (kWh) |
|---|
Is it the right size?
A heat pump that is too small leaves the backup heat working; one that is too big runs in short bursts. Here is what your room needs in extreme cold.
- Room need at −25 °C
- Heat pump heat at −25 °C
- Need at −30 °C
- Heat pump heat at −30 °C
Our buying guide
| Open area | Capacity |
|---|---|
| 700 to 1,000 sq ft | 12,000 BTU |
| 1,000 to 1,300 sq ft | 15,000 BTU |
| 1,300 to 1,600 sq ft | 18,000 BTU |
| 1,600 to 1,900 sq ft | 24,000 BTU |
Payback
Hydro-Québec’s LogisVert subsidy is paid once; the savings come back every year. Enter your quote price to see how long the heat pump takes to pay for itself.
- LogisVert subsidy
- Your cost after the subsidy
- The heat pump pays for itself in
The 40 wall-mounted heat pumps we install, for your home
Same room, same winter, same electricity price: each model’s savings. Tap a column heading to sort, “Choose” to redo the whole calculation with another model.
For your home, your choice ranks .
| Model | Savings per year | Cost per year with it | Heat supplied | Max. heat at −25 °C (BTU/h) | Heats down to | SEER2 | HSPF2 region V | Subsidy | Choose |
|---|
The calculation, step by step
Your figures, in the order the calculation produces them.
Every assumption, adjustable
The default values are those of a typical Québec home. If you know yours better, change them: the whole calculation follows.
Frequently asked questions
Will my savings be exactly these?
No: it is an estimate, and a serious one. It replays ten real winters with each unit’s certified ratings. Your bill also depends on your habits, your windows, the doors you close and where the unit is placed. The order of magnitude is reliable; an advisor fine-tunes it at your home.
Why the HSPF2 region V rating?
Manufacturers certify two seasonal heating ratings: region IV, a temperate climate, and region V, a cold climate, the closest to Québec. We use region V for every model: the same rule for all, and the most cautious.
Why only one room, and not the whole house?
A wall-mounted heat pump heats the room where it is installed and the open rooms connected to it. Enter the area it really serves. For the whole house, a multi-zone or central heat pump is a better fit: we size it on site.
What happens when it gets colder than the unit’s limit?
It stops, and your baseboards or furnace take over. The calculation counts those hours, at the price of electricity or fuel. That is why a “cold climate” model saves more in Québec.
Why can cooling add a cost?
If you have no air conditioner today, the heat pump brings you new comfort in summer: the calculation honestly adds it to the bill afterwards. If you have a window air conditioner, the heat pump uses two to three times less electricity for the same cooling.
Which electricity price is used?
Hydro-Québec Rate D as of April 1, 2026. In winter, heating lowers the 2nd tier: 11.142¢ per kWh (12.81¢ with taxes). In summer, cooling is billed at the 1st-tier price: 7.065¢ (8.12¢ with taxes). You can change them in step 3.
Is the subsidy counted in the savings?
No: it is shown separately. Hydro-Québec pays it once, under LogisVert, and it lowers the cost of the unit in the payback calculation. The savings, on the other hand, come back every year.
What about defrosting and the base pan heater?
Defrosting is included in the certified HSPF2 rating. The base pan heater, which keeps the outdoor unit’s base free of ice, is not counted for any model: few manufacturers publish its power. Allow about 100 kWh per year.
How do I choose the capacity?
Our buying guide gives the order of magnitude based on the open area; the “Is it the right size?” chapter checks the heat in extreme cold. An advisor confirms on site, free of charge.
I heat with oil or propane
Choose it in step 3 and enter the price of your last delivery. The heat pump supplies the heat with electricity; the furnace is only used as backup, in extreme cold.
For which region is this calculated?
For the Laval area. Laval lies between Trudeau airport and Mirabel airport: the calculation takes, hour by hour, the average of the two stations over ten years (2016 to 2025). Mirabel is a little colder, with 318 hours per year below −15 °C versus 182 at Trudeau; the average counts 250. In Montréal, the savings are slightly lower; further north, slightly higher.
Sources and method
Every document consulted, on November 2, 2026.
- NEEP listings for the 40 models (AHRI-certified data: capacity at each temperature, seasonal ratings)
- ENERGY STAR database of certified heat pumps
- List of heat pumps eligible for LogisVert (Hydro-Québec)
- Electricity rates as of April 1, 2026 (Hydro-Québec)
- Historical hourly climate data (Environment Canada)
- Fujitsu ASUH09-15KTAS technical manual (Orion+ XLTH heat below −20 °C)
The calculation uses, degree by degree and month by month, the hours at each temperature recorded from 2016 to 2025 by Environment Canada at the Trudeau and Mirabel airports (87,600 hours per station), whose average represents the Laval area. The room’s heat need follows your area, your insulation and your set temperature. The heat pump supplies what its certified capacity allows at each temperature (NEEP listing, AHRI data); below its operating limit, or when its capacity is no longer enough, backup heat makes up the rest. Its consumption follows its certified HSPF2 region V seasonal rating, the coldest, defrosting included. In summer, the cooling need follows the hours above 22 °C, and consumption the SEER2 rating. Heating oil and propane: 38.7 and 25.3 MJ per litre (Natural Resources Canada), at your furnace’s efficiency. An estimate: actual consumption also depends on your habits, your windows and where the unit is placed.
Get your free quote in 30 seconds — no commitment.
- ✅ 100% free evaluation
- ✅ Fast response
- ✅ 30+ certified employees
- ✅ No subcontractors